Features:
  • Display 6600 counts

  • Auto & Manual Ranging

  • Auto power off

  • True RMS for AC voltage & AC current

  • DAR/PI Mode

  • Relative measurement

  • Continuity buzzer <30Ω

  • Diode open voltage 2.4V

  • Low Pass Filter function (1kHz)

  • LOCK

  • Data logging 100 groups

  • Data recording

  • MAX / MIN / AVG

  • Data hold

  • Display backlight

  • Low battery display

More About The MS5208
Information:

safety rating

  • CAT IV 600V, CAT III 1000V

display counts

  • 6600

true rms

  • Yes

non-contact voltage

  • No

auto ranging

  • Yes

dc current

  • 400mA

ac voltage

  • 750V

ac current

  • 400mA

dc voltage

  • 1000V

display backlight

  • Yes

auto power off

  • Yes

data hold

  • Yes

battery test

  • Yes

overrange indication

  • No

hfe transistor

  • No

low battery indicator

  • Yes

duty cycle

  • Yes

diode

  • Yes

continuity

  • Yes

resistance

  • 66MΩ

capacitance

  • 66mF

frequency

  • 10kHz

  • Yes

temperature

  • -301300°C / -222372°F

  • Yes

dar/pi

  • Yes

insulation test

  • Yes

dual display

  • No

overload protection

  • No

relative measurement

  • Yes

peak measurement

  • Yes

low pass filter

  • Yes

sound & light warning

  • No

low impedance

  • No

bar graph

  • No

analysis software

  • No

dwell test

  • No

tach test

  • No

logic level test

  • No

retractable tip

  • No

double molding

  • No

max/min/avg

  • MAX / MIN / AVG

work light

  • Yes

interface

  • No

type k temperature

  • -301300°C / -222372°F

Specifications:

DC Voltage

  • Range

    • 660mV / 6.6V / 66V / 660V / 1000V

  • Resolution

    • 0.1mV / 1mV / 10mV / 0.1V / 1V

  • Accuracy

    • ±(0.5%+5)

AC Voltage

  • Range

    • 660mV / 6.6V / 66V / 660V / 750V

  • Resolution

    • 0.1mV / 1mV / 10mV / 0.1V / 1V

  • Accuracy

    • ±(1.5%+30)

DC Current

  • Range

    • 66mA / 400mA

  • Resolution

    • 10μA / 0.1mA

  • Accuracy

    • ±(1.0%+5)

AC Current

  • Range

    • 66mA / 400mA

  • Resolution

    • 10μA / 0.1mA

  • Accuracy

    • ±(1.5%+30)

Resistance

  • Range

    • 660Ω / 6.6kΩ / 66kΩ / 660kΩ / 6.6MΩ / 66MΩ

  • Resolution

    • 0.1Ω / 1Ω / 10Ω / 0.1kΩ / 1kΩ / 10kΩ

  • Accuracy

    • ±(1.2%+5) for ≤6.6MΩ

    • ±(2.0%+20) for 66MΩ

Capacitance

  • Range

    • 66nF / 660nF / 6.6μF / 66μF / 660μF / 6.6mF / 66mF

  • Resolution

    • 10pF / 0.1nF / 1nF / 10nF / 0.1μF / 1μF / 10μF

  • Accuracy

    • ±(5.0%+20)

Frequency

  • Range

    • 660.0Hz / 6.600kHz / 66.00kHz / >10kHz

  • Resolution

    • 0.1Hz / 1Hz / 10Hz / 10Hz

  • Accuracy

    • ±(1.5%+5)

    • Reference for >10kHz

Temperature

  • Range

    • -30℃~1300℃ / -22℉~2372℉

  • Resolution

    • 1℃ / 1℉

  • Accuracy

    • ±(1.0%+2) for ℃

    • ±(1.0%+4) for ℉

Insulation function

50V (0~20%)

  • Range

    • 0M5MΩ / 5M50MΩ

  • Resolution

    • 0.01MΩ / 0.1MΩ

  • Accuracy

    • ±(3.0%+5)

  • Test current

    • 1mA @ 50kΩ

100V (0~20%)

  • Range

    • 0M5MΩ / 5M50MΩ / 50M~100MΩ

  • Resolution

    • 0.01MΩ / 0.1MΩ / 1MΩ

  • Accuracy

    • ±(3.0%+5)

  • Test current

    • 1mA @ 100kΩ

250V (0~20%)

  • Range

    • 0M25MΩ / 25M250MΩ

  • Resolution

    • 0.1MΩ / 1MΩ

  • Accuracy

    • ±(3.0%+5)

  • Test current

    • 1mA @ 250kΩ

500V (0~20%)

  • Range

    • 0M50MΩ / 50M500MΩ

  • Resolution

    • 0.1MΩ / 1MΩ

  • Accuracy

    • ±(3.0%+5)

  • Test current

    • 1mA @ 500kΩ

1000V (0~20%)

  • Range

    • 0M50MΩ / 50M500MΩ / 0.5G~2.0GΩ

  • Resolution

    • 0.1MΩ / 1MΩ / 0.1GΩ

  • Accuracy

    • ±(3.0%+5) (up to 500MΩ)

    • ±(5.0%+5) (0.5GΩ~2.0GΩ)

  • Test current

    • 1mA @ 1000kΩ

bottom of page