CMP-1006 Clamp Meter
Measurement:
-
AC/DC current measurement (TRUE RMS) up to 1000A
-
Measurement of INRUSH current in start-up phase of electrical device
-
(high frequency of sampling)
-
AC/DC voltage measurement (TRUE RMS) up to 600V.
-
Resistance measurement and continuity test: - continuity test with acoustic signalling (beeper) for resistance below 40Ω.
-
Temperature measurement (Fahrenheit and Celsius units).
-
Frequency measurement.
-
Duty cycle measurement.
-
Diode test.
Key Features:
-
Safe, insulated measuring clamps,
-
Autoranging/manual range selection,
-
„DATA HOLD” function, for holding measured values,
-
backlit LCD,
-
„DC ZERO” mode of measurement for DC current, possibility to zero the display and reading relative actual value less stored „zero” value,
-
„MAX/MIN” function,
-
over range indication,
-
„AUTO-OFF” function.
Specifications:
Electrical safety
- measurement category CAT III 600V acc. to EN 61010-1:2004
- protection class acc. to EN 60529 IP40
Other technical specifications
- power supply .............................................................................9V battery type 6LR61
- display ...................................................................................6600 counts, backlit LCD
- continuity test ........................................................threshold 40 ; test current < 0,5mA
- diode test........................................................................ test current of 0,3mA, typical
open circuit voltage < 3V DC, typical
- low battery indication............................................................................. BAT displayed
- over range indication................................................................................ 0L displayed
- sampling rate................................................................................. 2 times per second
- INRUSH................................................................................... integration time 100ms
- temperature sensor..................................................................... type K thermocouple
- input impedance....................................................................... 10M (V DC and V AC)
- AC bandwidth................................................................. 50...400Hz (A AC and V AC)
- auto power OFF................................................................................... approx. 25 min.
- dimensions....................................................................................... 229 x 80 x 49 mm
- weight.................................................................................................................. 303 g
- accordance with following standards.................... EN 61010-1:2004 EN 61010-2-032
- quality standard............................................................................................. ISO 9001
Rated operational conditions:
- internal clamp diameter.............................................................. d1=36mm/d2=52mm
- operating temperature................................................................................. +5...+50°C
- storage temperature................................................................................... -20...+60°C
- operating humidity max....................................................................... 80% up to 31°C
decreasing linearly to 50% at 40°C
- storage.................................................................................................. humidity <80%
- operating altitude...................................................................................... max 2000 m
.*For full Technical Specifications, please refer to PDF Data Sheet
Standard Accessories:
- test leads (2 pcs.)
- battery 9V
- K type temperature probe
- carrying case
- operating manual