top of page
MS2301
Features:
  • Display 9999 counts.

  • Jaw Opening 45mmx32mm/1.8"x1.3".

  • Logging and Recall 99 groups.

  • Setting Alarm Threshold in 1~100Ω.

  • Low Battery Display.

  • Buzzer ON Symbol.

  • Data hold.

More About The MS2301
Information:

display counts

  • 9999

ac current

  • 20A

3 pole & 4 pole resistance

  • No

resistance

  • 1200Ω

data hold

  • Yes

resistivity of soil

  • No

overrange indication

  • No

low battery indicator

  • Yes

backlight

  • No

data logging

  • 99 groups

Specifications:

earth resistance

  • 0.01Ω~0.999Ω

    • Range: 0.01Ω~0.999Ω

    • Resolution: 0.001Ω

    • Accuracy: ±(1.5%+0.01Ω)

  • 1Ω~9.99Ω

    • Range: 1Ω~9.99Ω

    • Resolution: 0.01Ω

    • Accuracy: ±(1.5%+0.3Ω)

  • 10Ω~99.9Ω

    • Range: 10Ω~99.9Ω

    • Resolution: 0.1Ω

    • Accuracy: ±(3.0%+0.3Ω)

  • 100Ω~199.9Ω

    • Range: 100Ω~199.9Ω

    • Resolution: 1Ω

    • Accuracy: ±(5.0%+3Ω)

  • 200Ω~400Ω

    • Range: 200Ω~400Ω

    • Resolution: 5Ω

    • Accuracy: ±(6.0%+5Ω)

  • 400Ω~500Ω

    • Range: 400Ω~500Ω

    • Resolution: 10Ω

    • Accuracy: ±(10%+10Ω)

  • 500Ω~1200Ω

    • Range: 500Ω~1200Ω

    • Resolution: 20Ω

    • Accuracy: approx. 20%

current

  • 100mA

    • Range: 100mA

    • Resolution: 0.1mA

    • Accuracy: ±(2.5%+1mA)

  • 300mA

    • Range: 300mA

    • Resolution: 0.3mA

    • Accuracy: ±(2.5%+2mA)

  • 1A

    • Range: 1A

    • Resolution: 0.001A

    • Accuracy: ±(2.5%+0.003A)

  • 3A

    • Range: 3A

    • Resolution: 0.003A

    • Accuracy: ±(2.5%+0.01A)

  • 10A

    • Range: 10A

    • Resolution: 0.01A

    • Accuracy: ±(2.5%+0.03A)

  • 20A

    • Range: 20A

    • Resolution: 0.03A

    • Accuracy: ±(2.5%+0.05A)

bottom of page