PAT-820 / 815 / 810  Portable Appliance Testers
PAT-820
Software:
Key Features:
  • intuitive user interface, with large 7" touch display

  • manual tests and auto tests, the ability to describe auto test with standards or any name,

  • flash test / high voltage test (only PAT-820),

  • typing with QWERTY keyboard on the touch screen,

  • description of test equipment, measurement location, customer data, assigning the serial number of the device under test and the index can be stored in meter memory, ability to write notes about the device under the test

  • base of the appliances, customers, description of the equipment and damage.

  • the results can be printed (also automatically after every measurement), reports (works with the printer), two labels can be printed after a single test (for the device and a removable wire)

  • support for barcode reader (including 2D), readings of the original serial numbers for the appliances and registration codes and auto test codes,

  • automatic measurement of RCD parameters

  • build-in help with instructions how to connect test equipment and how to perform measurement,

  • ability to create many user accounts with log-in function (as an option),

  • supports USB flash drive;

  • communication with PC via USB and WiFi;

  • works with the program Sonel PAT Reader and Sonel PAT; measurement and settings configuration from the meter and also
    from PC, data analysis.

Sonel PAT plus software is designed for companies carrying out testing of portable electrical appliances.

 

It is ideal solution for big industrial companies, rent and service of electrical appliances etc. Sonel PAT plus communicates with PAT testers. All data saved in tester memory are transferred automatically to proper tables in the software.

Tests can be printed out in 4 versions:

» Test report – shows on one page all tests and all features of

   appliance.

» History of tests – shows in one table all test results. » Short

   history of tests – prints basic information about test of

   appliance.

» Summary report - sorted according to the category of

   measurement.

 

This option enables to add new print data on existing appliance card. Complete documentation can be also saved to PDF file. All data and test results are administered by Scheduler. For every appliance user set "Test cycle" Thanks to this function software automatically displays appliances with overdue test validity and can send email notification to the customer.

Basic Functions:                           
  • measurement of earth bond/continuity resistance with the currents:

       200 mA (PAT-810/815/820), 10 A and 25 A (only PAT-815/820) 

       (protection class I),

  • measurement of insulation resistance – three measurement voltages:

      100 V and 250 V (only PAT-815/820), 500 V (PAT-810/815/820),

  • measurement of substitute leakage current,

  • measurement of differential leakage current,

  • measurement of touch leakage current,

  • measurement of power,

  • measurement of current consumption,

  • IEC lead test,

  • check of the L-N circuit test,

  • measurement of mains voltage and frequency,

  • RCD testing,

  • flash test / high voltage test (only PAT-820).

Specifications:

Electrical safety:

- insulation according to                                                       EN 61010-1 and IEC 61557

- measurement category                                                        II 300V acc.to EN 61010-1

- enclosure protection rating acc. to EN 60529:                     IP40 (IP67 with lid closed)

Other technical data:

- power supply of the meter..................................................................195...265V, 50Hz

- load current.........................................................................................max. 16A (230V)

- data transfer to a PC........................................................................ ............... USB 2.0

- dimensions.....................................................................................330 x 235 x 120 mm

- weight of the meter..................................................................................approx. 6.2 kg

Nominal operating conditions:

- operating temperature ................................................................................-10...+50°C

- storage temperature....................................................................................-20...+70°C

- humidity...........................................................................................................20...80%

.*For full Technical Specifications, please refer to PDF Data Sheet

Standard Accessories of the PAT-806:

- power supply cord

- test lead 1,8 m; SP-4 plug, orange

- test lead with banana plug; 1.8 m; 5 kV; red (only PAT-820 - 2 pcs)

- pin probe 5kV with banana connector - red (only PAT-820 - 2 pcs.)

- USB cable

- fuse 0314 015.VXP 15 A 250 VAC 6.3x32 mm Littlefuse 2 pcs

- instruction manual

- warranty card

Optional Accessories:

- adapter IEC 60320 C6 Plug to IEC 60320 C13 Connector Block

- current clamp C-3 (only for PAT-820/815)

- three phase socket adapter 16A

- three phase socket adapter 16A switchable

- three phase socket adapter 32A

- three phase socket adapter 32A switchable

- adapter for industrial sockets 16A

- adapter for industrial sockets 32A

- cable - adapter Shuko / IEC (for testing extensions)

- Sonel PAT+ software

- USB barcode reader

- portable USB report/bar code printer