P-1 / 2 / 3  VOLTAGE AND CONTINUITY TESTERS
P-1 / 2 / 3
Key Features:
  • The P series indicators allow for voltage measurement even with discharged batteries.

  • P-3 is the only indicator allowing for phase identification.

Specifications:

Electric security:

- type of insulation double,                                                       according to EN 61010-1

- measurement category                           CAT III 1000V (IV 600V) acc. to EN 61010-1

- protection class  acc. to EN 60529                                                                        IP65

Other technical data:

- meter’s power supply....................................... alkaline batteries LR03 (AAA) (2 pcs.)

- frequency range for a single-pole phase indicator...................................... 50...400Hz

- accuracy of voltage indications.................................. in accordance with EN 61243-3

Nominal operating conditions:

- operation temperature............................................................................... -10...+55°C

- voltage frequency range for the diode bar.................................................. 15...400Hz

- maximum measurement current................................................. I <0,2A/I (5s)<3,5mA

.*For full Technical Specifications, please refer to PDF Data Sheet

Standard Accessories:
Indication and measurement of direct and alternating voltages:

- indication on the LED bargraph: 12, 24, 50, 120, 230, 400, 690 V

  (also operates without batteries),

- display of the measurement result on the LCD screen,

- determining voltage: alternating or polarity of direct voltage.

Measurement of resistance and circuit continuity:

- display of the measurement result on the LCD screen,

- signalling for resistance < 400 kΩ.

Phase rotation indicator:

- indication of phase sequence for voltage > 100 V.

Single-pole phase determination:

- indication with the use of the touch electrode,

- optical and acoustic signalling for voltage > 50 V.

Residual current device test:

- testing RCDs of I ≤ 100 mA. Δn

Phase identification and phasing (P-3 only):

- determining phase at a given point in reference to some other 

  point,

- capability of determining phase at a given point with the use of an

  additional transmitter - no time limit related to the synchronisation

  of power system.

 

- batteries LR03 (AAA) (2 pcs.)

- operating manual

 

transmitter LKN-710P

(P-3 only)

Optional Accessories:

- transmitter LKN-710P (P-3 only)

- carrying case S2