MS8250D
Features:
-
Display 6600 counts
-
Auto Ranging
-
Manual Ranging
-
Auto Power Off
-
Relative Measurement
-
True RMS
-
Non-Contact Voltage Detector
-
Diode Open voltage 3.2V
-
Continuity Buzzer <50Ω
-
MAX/MIN
-
Bar Graph
-
Data Hold
-
Low Battery Display
-
Display Backlight
-
USB Interface Windows OS
More About The MS8250D
Information:
safety rating
-
CAT IV 600V, CAT III 1000V
display counts
-
6600
true RMS
-
Yes
non-contact voltage
-
Yes
auto ranging
-
Yes
dc current
-
10A
ac voltage
-
1000V
ac current
-
10A
dc voltage
-
1000V
display backlight
-
Yes
auto power off
-
Yes
data hold
-
Yes
battery test
-
No
overrange indication
-
No
hFE transistor
-
No
low battery indicator
-
Yes
duty cycle
-
Yes
diode
-
Yes
continuity
-
Yes
resistance
-
66MΩ
capacitance
-
66mF
frequency
-
66MHz
-
Yes
temperature
-
No
DAR/PI
-
No
insulation test
-
No
dual display
-
Yes
overload protection
-
No
relative measurement
-
Yes
peak measurement
-
No
low pass filter
-
No
sound & light warning
-
Yes
low impedance
-
No
bar graph
-
No
analysis software
-
No
DWELL test
-
No
TACH test
-
No
logic level test
-
No
retractable tip
-
No
double molding
-
No
MAX/MIN/AVG
-
MAX/MIN
work light
-
No
interface
-
USB
Specifications:
dc voltage
-
range: 660mV, 6.6V, 66V, 660V, 1000V
-
resolution: 0.1mV, 1mV, 10mV, 0.1V, 1V
-
accuracy: ±(0.8%+3), ±(0.5%+5)
ac voltage
-
range: 660mV, 6.6V, 66V, 660V, 1000V
-
resolution: 0.1mV, 1mV, 10mV, 0.1V, 1V
-
accuracy: ±(1.5%+5), ±(1.2%+5), ±(1.0%+3)
dc current
-
range: 660μA, 6600μA, 66mA, 660mA, 10A
-
resolution: 0.1μA, 1μA, 10μA, 0.1mA, 10mA
-
accuracy: ±(1.0%+5), ±(2.0%+5)
ac current
-
range: 660μA, 6600μA, 66mA, 660mA, 10A
-
resolution: 0.1μA, 1μA, 0.01mA, 0.1mA, 10mA
-
accuracy: ±(1.5%+5), ±(3.0%+5)
resistance
-
range: 660Ω, 6.6kΩ, 66kΩ, 660kΩ, 6.6MΩ, 66MΩ
-
resolution: 0.1Ω, 1Ω, 10Ω, 0.1kΩ, 1kΩ, 10kΩ
-
accuracy: ±(0.8%+5), ±(1.5%+5)
capacitance
-
range: 6.6nF, 66nF, 660nF, 6.6μF, 66μF, 660μF, 6.6mF, 66mF
-
resolution: 1pF, 10pF, 0.1nF, 1nF, 10nF, 0.1μF, 1μF, 10μF
-
accuracy: ±(4.0%+5), ±(3.0%+3), ±(4.0%+5)
frequency
-
range: 66Hz, 660Hz, 6.6kHz, 66kHz, 660kHz, 6.6MHz, 66MHz
-
resolution: 0.01Hz, 0.1Hz, 1Hz, 10Hz, 0.1kHz, 1kHz, 10kHz
-
accuracy: ±(1.5%+5)
duty cycle
-
range: 0.1% ~ 99.9%
-
resolution: 0.1%
-
accuracy: ±(2.0%+5)