top of page
MRU-30  Earth Resistance Meter
MRU-30
Key Features:
  • earth resistance measurement with 3-pole, 4-pole method,

  • selective earth resistance measurement with clamp (no influence from parallel earths; no opening of rusty junctions is needed),

  • continuity of eqipotential bondings and protecting conductors,

  • two clamps earth resistance measurement without auxiliary test probes,

  • earth resistivity measurement.

  • measurement of resistance of auxiliary electrodes RS and RH,

  • measurement of interference voltage,

  • measurement in the presence of interference voltage in the power network with frequency 50Hz, 60Hz,

  • selection of maximum measuring voltage (25V and 50V),

  • introducing the distance between the electrodes for the resistivity

       in metres (m) and feet (ft),

  • memory of 990 measurements (10 banks of 99 cells each),

  • calibration of clamp used,

  • data transmission to the computer (USB),

  • indication of battery state.

It allows to take the measurements of:

- earthing resistance using auxiliary electrodes

- earthing resistance using auxiliary electrodes and clamp (for

  measurements of multiple earthing)

- earthing resistance using double clamps (for measurement of

  earthing when it is impossible to use auxiliary electrodes),

- ground resistivity (Wenner method)

- continuity of equipotential bondings and protective

- conductors (meeting the requirements IEC 60364) with auto-zero

  function – with current 200mA.

Measurements of soil resistivity (with Wenner method):

- input of probes spacing distances in metres (m) or in feet (ft).

Measurements of protective connection and equipotential
bonding continuity:

measurement range to IEC 61557-4:2007: 0,13 Ω...1999 Ω

Specifications:

Electrical safety

- type of insulation:                     double, according to EN 61010-1and IEC 61557, EMC

- measurement category:                                             CAT III 300V acc. to EN 61010-1

- protection class acc. to EN 60529                                                                          IP65

Rated operational conditions:

- operation temperature................................................................................ -10...+55°C

- storage temperature................................................................................... -20...+80°C

- humidity.......................................................................................................... 20...90%

Other technical data:

- LCD display........................................................................................ segment, backlit

- dimensions......................................................................................... 200x150x74 mm

.*For full Technical Specifications, please refer to PDF Data Sheet

Standard Accessories for the MRU-30:
Optional Accessories:

- earth contact test probe (rod); 0,3m

- test lead with banana plug; 1,2m; red

- test lead with banana plug; 2,2m; black

- test lead on a reel with banana plug; 25m; red

- test lead on a reel with banana plug; 50m; yellow

- „crocodile” clip K01; black

- pin probe with banana plug; red

- USB transmission cable

- Sonel Reader software

- power supply adaptor Z7

- carrying case M9

- carrying case L10

- earth contact test probe (rod); 0,8m;

- current clamp N-1 (Ø=52mm)

- current clamp C-3 (Ø=52mm)

- carrying case L3

- charger for battery loading from the socket of car lighter (12V)

- calibration certificate issued by calibration laboratory

- Test lead with banana plugs 2m (N-1)

- „Crocodile” clip K02; red

- Cramp

 

bottom of page