MPI-505  Multifunction Electrical Installation Meter
MPI-505
Key Features:
  • MPI-505 meter has improved immunity to unfavourable operating conditions.

 

  • Quick verification of correctness of the PE conductor connection with the use of a touch electrode.

  • Phase sequence checking.

  • Memory of 990 measurements (57500 individual results), data transfer to a PC over the USB or wireless interface.

  • Battery or rechargeable battery power supply.

  • Real time clock (RTC) - measurement time saved in memory.

Low-voltage measurement of protective connection
and equipotential bonding resistance:

- measurement of the protective conductor continuity with current 200 mA

  in both directions (in accordance with the EN 61557-4 standard),

- low-current measurement of resistance with acoustic and light signalling,

- automatic calibration of test leads - capability of using test leads of any

  length.

Specifications:
Measurement of short-circuit loop impedance:

- impedance measurement in power systems of rated voltages:

  115/200 V, 127/220 V, 220/380 V, 230/400 V, 240/415 V and

  frequencies of 45...65 Hz,

- measurement of short-circuit loop impedance with current 15 mA

  with the resolution of 0.01Ω, without tripping residual current

  devices.

Electrical safety

- type of insulation:                     double, according to EN 61010-1and IEC 61557, EMC

- measurement category:                                                    IV 300 V acc. to EN 61010-1

- protection class acc. to EN 60529:                                                                         IP54

.*For full Technical Specifications, please refer to PDF Data Sheet

Standard Accessories:
Examination of AC, A and B type residual current devices:

- measurement of general use and selective RCDs of rated residual

  current 10, 30, 100, 300, 500 and 1000 mA,

- measurement of the I tripping current, A

- measurement of the t tripping time for 1/2I , I , 2I , 5I , A Δn Δn

  Δn Δn

- measurement of earthing continuity and touch voltage without

  tripping RCDs,

- a function of automatic measurement of residual current device

  parameters.

Insulation resistance measurement:

- four test voltages for insulation resistance measurement: 100 V,

  250 V, 500 and 1000 V.

Optional Accessories for the MPI-525:

- Adapter with START button with UNI-Schuko (WS-01)

- Test lead with banana plug; 1,2m; red

- Test lead with banana plug; 1,2m; yellow

- Test lead with banana plug; 1,2m; blue

- USB cable

- Pin probe with banana connector; red

- Pin probe with banana connector; yellow

- Pin probe with banana connector; blue

- "Crocodile" clip K02; yellow

- "Crocodile" clip K02; red

- Carrying case L4

- Hanging straps

- Calibration certificate, Sonel Reader software, batteries

- 5 m red test lead terminated with a banana plug

- 10 m red test lead terminated with a banana plug

- 20 m red test lead terminated with a banana plug

- WS-05 adapter with a UNI-Schuko plug

- AGT-16C adapter for 4-contact 3-phase sockets

- AGT-16P adapter for 5-contact 3-phase sockets

- AGT-16T adapter for industrial sockets

- AGT-32C adapter for 4-contact 3-phase sockets

- AGT-32P adapter for 5-contact 3-phase sockets

- AGT-32T adapter for industrial sockets

- AGT-63P adapter for 5-contact 3-phase sockets

- TWR-1J adapter for testing RCD breakers

- “SONEL Pomiary Elektryczne” program for creating reports

- “SONEL Schematic” prog. for creating drafts, electr. inst. schem.

- “SONEL PE Kalkulacje” program for creating measurement calc.

- official calibration certificate

 