SPS-331 AC & DC Power Source
SPS-331-AC-DC-Standard-Power-Source_edit

*PDF Currently Unavailable

About the SPS-331:
  • Signal: AC (3 phase) & DC
    Accuracy: Class 0.05 or Class 0.1
    AC voltage output: 0-792V
    AC current output: 0-36A
    DC voltage output: 0-1100V
    DC current output:0-30A

     

  • SPS-331 Support various tests including indicating meter, digital meter, energy meter, etc. At the same time, it output 2nd ~63rd harmonics. 

  • High stability, low waveform distortion;

  • 8 inch color touch screen, interface friendly, easy to operate;

  • Equipped with RS232, Ethernet, and WiFi interface, SPS-331 can either support stand-alone operation, PC control or handy wireless terminal control;

  • Communicate with tested meter thru RS485;

  • Customize and develop the automatically adjustment and calibration system;

  • Self-protection, alarming and displaying overload location for equipment output overload, Voltage short-circuit, Current open-circuit;

  • Automatically detect, diagnose and alarm for failure.

  • Remotely updating online, easily achieve software updating;

  • Supports calibration at users’ side.

SPS-331 contains 2 models with different accuracy below:

  • SPS-331C, Accuracy Class: 0.05

  • SPS-331B, Accuracy Class: 0.1

Specifications:

AC Voltage Output

  • Range: 100V, 220V, 380V

  • Adjustment Range: (0~120) %RG; RG refers to range

  • Adjust resolution: 0.01%RG, 0.1%RG, 1%RG, or 10% RG

  • Stability: 0.005%/1min (Class 0.05), 0.01%/1min (Class 0.1)

  • Distortion: ≤0.1% (Non capacitive load)

  • Max output load: 25V /phase (resistance load)

  • Measurement accuracy: 0.05%RG (Class 0.05); 0.1%RG (Class 0.1)

AC Current Output

  • Range: 0.05A, 0.2A, 1A, 5A, 20A, 100A

  • Adjusting range: (0~120) %RG, RG refers to range

  • Adjusting resolution: 0.01%RG, 0.1%RG, 1%RG, or 10% RG

  • Stability: 0.01%/2min (Class 0.05), 0.02%/2min (Class 0.1)

  • Distortion: ≤0.2% (Non capacitive load)

  • Max output load: 120VA (120A range)

  • Measurement accuracy: 0.05%RG (Class 0.05); 0.1%RG (Class 0.1)

Power Output

  • Power output stability: 0.01%/2min (Class 0.05), 0.02%/2min (Class 0.1)

  • Active/reactive power measurement accuracy: 0.05%RG (Class 0.05); 0.1%RG (Class 0.1)

Phase Output

  • Output adjusting range: 0°~360°

  • Output adjusting resolution: 10°, 1°, 0.1°, or 0.01°

  • Resolution: 0.01°

  • Measurement accuracy: 0.05°

Power Factor Output

  • Adjusting range: -1 ~ 0 ~ +1

  • Measuring resolution: 0.0001

  • Measurement accuracy: 0.0005

Frequency Output

  • Adjusting range: 40Hz ~70Hz

  • Output adjusting resolution: 1Hz, 0.1Hz, 0.01Hz, or 0.001Hz

  • Resolution: 0.001Hz

  • Accuracy: 0.001 Hz

Harmonic Setting

  • Harmonic order: 2nd ~63rd

  • Harmonic amplitude: 0~40%

  • Harmonic angle: 0°~359.99°

  • Harmonic set error: 2nd31st: ≤±0.1%, 32nd63rd: ≤±0.2%

Energy Error Measurement

  • Active energy basic error limit:

    • ±0.05%RD (Voltage 15V660V, Current 0.02A120A, PF≥0.5)

    • ±0.1%RD (Voltage 15V660V, Current 0.01A0.02A, PF=1)

  • Reactive energy basic error limit:

    • ±0.1%RD (Voltage 15V660V, Current 0.02A120A, PF≥0.5)

    • ±0.2%RD (Voltage 15V660V, Current 0.01A0.02A, PF=1)

Other Parameters

  • Power supply: 90-265VAC/DC

  • Power frequency: 50Hz~60Hz

  • Power consumption: 50VA~1000VA

  • Environment condition: 20℃~30℃, Humidity: RH≤85%

  • Storage environment: -20℃~50℃

  • Size: 600mm (L) × 440mm (W) × 176mm (H)

  • Weight: 35kg