VLF-34 SMT
VLF SMT Series_edited.png
Introduction to the VLF-34 SMT:
  • Withstand voltage test is an essential preventive test for electrical equipment.

  • It is divided into two parts: AC and DC withstand voltage test. AC test can be further divided into power frequency, variable frequency and 0.1Hz very low frequency test, among which the last one is highly recommended by IEC, due to its remarkable advantages.

  • VLF testing is the substitute for power frequency test.

  • It is suitable for testing electrical equipment with large capacitance (like power cable, power capacitor, motor, and generator).

Specs

VLF-34

  • Rated Voltage: 30kV (peak value)

  • Load Capacitance:

    • 0.1Hz, ≤1.1µF

    • 0.05Hz, ≤2.2µF

    • 0.02Hz, ≤5.5µF

  • Power Fuse: 8A

  • Structure & Weight: One piece, about 30kg

VLF-34 SMT / VLF-63 & 80 SMT
Key Features:
  • The new generation of VLF series 0.1Hz VLF AC Hipot Test Set developed “Smart Quick” intelligent power test system introduced the latest international power electronic components and the latest ARM7 microcontroller technology, further reducing the size and weight of the equipment. The operation is easier, and the performance is stable.

  • Advanced technology adopts digital frequency conversion technology, fully automatic micro computer control, voltage boost, step-down, measurement, protection, etc.

  • Control part and High-voltage part adopt an integrated structure design, and only a high voltage wire and ground wire are needed to connect to the tested product without the intermediate connection wire.

  • Trolley-style design is convenient for transportation in various working environments, and its small size and light weight are very conducive to outdoor operations (34/63/80kV Models).

  • Over-voltage protection and over-current protection. Action time is no longer than 10ms.

  • The control unit and the booster are connected at low voltage, with photoelectric isolation control, safe and reliable to use.

  • Closed-loop negative feedback circuit is adopted. No capacity rising during outputting.

  • Capacitive touch screen, LCD graphic display, automatic storage, and printing.

  • 0.1Hz, 0.05Hz and 0.02Hz can be chosen, which ensures a wide test range.

  • Peak voltage: 30kV, 60kV or 80kV, sine wave

  • Test frequency: 0.1Hz, 0.05Hz and 0.02Hz (selectable)

  • Maximum load capacity:

    • 1.1 μF @0.1Hz

    • 2.2 μF @0.05Hz

    • 5.5 μF @0.02Hz

  • Measurement accuracy: ±1%

  • Voltage peak value error: ±1%

  • Voltage waveform distortion: 5%

  • Working environment: indoor or outdoor; 10℃--+40℃; 85%RH

  • Power supply: 220V ±10%, 50Hz ±
    (If using a portable generator, make sure the output voltage and frequency are stable)

  • Power >3kW

  • Capacitance of the tested object shall not exceed the max. rated capacitance of the instrument.