top of page
Sentinel Series Portable Appliance Testers
Sentinel Series.png
Introduction to the Sentinel Series
  • The Sentinel Series is a powerful and cost-effective range of electrical safety testers designed to meet the demands of production lines, compliance testing, and research environments. Whether in manufacturing, quality assurance, or R&D laboratories, the Sentinel Series ensures accurate, efficient, and reliable hipot testing, helping users meet international safety standards such as IEC, EN, UL, and CSA.

  • Offering both manual and automatic testing, the Sentinel Series includes models with AC and DC dielectric strength testing up to 5kV and 6kV, insulation resistance, and earth bond testing. With up to 500VA AC power output, the Sentinel Series delivers high-resolution measurement capabilities, ensuring precision in every test.

  • Designed for flexibility and ease of use, the Sentinel Series supports remote control via PLC, USB, and RS-232, making it ideal for automated testing setups. The sweep function allows real-time monitoring of test parameters over time, making it particularly useful for R&D applications. Additionally, enhanced safety features such as automatic voltage cut-off and rapid discharge protect both the user and the equipment under test.

  • With robust construction, advanced testing features, and seamless integration capabilities, the Sentinel Series is the ideal solution for engineers, compliance labs, and manufacturers seeking a comprehensive and efficient electrical safety testing system.

More About the Sentinel Series
Key Features
  • 500 VA capability (Sentinel 500 series)

  • Earth bond / insulation resistance (Sentinel 501)

  • Sweep function for test analysis

  • Flexible / high resolution test parameters

  • Manual / automatic test modes

  • Remote and PLC control

  • Fast cut off and automatic discharge

sent500.jpg

Sentinel 500

KeyUsers
sent501.jpeg

Sentinel 501

  • R&D Departments

  • Compliance Laboratories

  • Design Engineers

  • QA Departments

  • Production and Manufacturing Engineers

Compare the Sentinel Series
SentComp.png
Technical Specifications 

Sentinel 500/501 - AC Dielectric Strength

  • Programmable Voltage Range: 0.100 kV - 5.000 kV (2V/Step Resolution)

  • Frequency Independent of Supply: 50 or 60 Hz Selectable

  • Output Voltage Accuracy: ±1% + 5 Volts (No Load)

  • Voltage Display Resolution: 0.001kV

  • Current Measurement: 0.001mA - 100.0mA

  • Range and Accuracy:

    • ±1.5% + 30 Counts when trip limit <1.11mA

    • ±1.5% ± 3 Counts when trip limit >1.11mA

  • Current Display Resolution: 0.001mA / 0.001mA / 0.1mA

  • Selectable Range of Pass/Fail Levels: 0.001mA - 100.00mA

  • Maximum Rated Current:

    • 100mA (0.5kV ≤ V ≤ 5kV)

    • 10mA (0.1kV ≤ V ≤ 0.5kV)

  • Arc Detection: Yes

  • Ramp time: 0.1 - 999.9s

  • Test Time: Off / 0.5s - 999.9s

Sentinel 501 - Earth Bond

  • Programmable Test Current: 03.00A - 32.00A ac

  • Test Current Resolution: 0.01A

  • Test Current Accuracy:

    • 3A - 8A: (1% of rdg+0.2A)

    • 8A - 32A: (1% of rdg+0.05A)

  • Test Voltage: 6V AC max (open circuit)

  • Test Voltage Frequency: 50Hz/60Hz selectable

  • Resistance Measurement Range: 10mΩ - 650.0mΩ

  • Resistance Measurement Resolution: 0.1mΩ

  • Resistance Measurement Accuracy: (1% of rdg + 2mΩ)

  • Test Time: 0.5 - 999.9s

  • Arc Detection: Yes

Sentinel 200 - AC Dielectric Strength

  • Programmable Voltage Range: 0.100 kV - 5.000 kV (2V/Step Resolution)

  • Frequency Independent of Supply: 50 or 60 Hz Selectable

  • Output Voltage Accuracy: ±1% + 5 Volts (No Load)

  • Voltage Display Resolution: 0.001kV

  • Current Measurement: 0.001mA - 40.0mA

  • Range and Accuracy:

    • ±1.5% + 30 Counts when trip limit <1.00mA

    • ±1.5% ± 30 Counts when trip limit ≥1.00mA

  • Current Display Resolution: 0.001mA / 0.001mA / 0.1mA

  • Selectable Range of Pass/Fail Levels: 0.001mA - 40.00mA

  • Maximum Rated Current:

    • 40mA (0.5kV ≤ V ≤ 5kV)

    • 10mA (0.1kV ≤ V ≤ 0.5kV)

  • Arc Detection: Yes

  • Ramp time: 0.1 - 999.9s

  • Test Time: Off / 0.5s - 999.9s

Sentinel 500/501 - DC Dielectric Strength

  • Programmable Voltage Range: 0.100 kV - 6.000 kV (2V/Step Resolution)

  • Frequency Independent of Supply: 50 or 60 Hz Selectable

  • Output Voltage Accuracy: ±1% + 5 Volts (No Load)

  • Voltage Display Resolution: 0.001kV

  • Current Measurement: 0.001mA - 20.0mA

  • Range and Accuracy:

    • ±1.5% + 30 Counts when trip limit <1.11mA

    • ±1.5% + 3 Counts when trip limit >1.11mA

  • Current Display Resolution: 0.001mA / 0.001mA / 0.1mA

  • Selectable Range of Pass/Fail Levels: 0.001mA - 20.00mA

  • Maximum Rated Current:

    • 20mA (0.5kV ≤ V ≤ 5kV)

    • 2mA (0.1kV ≤ V ≤ 0.5kV)

  • Arc Detection: Yes

  • Ramp time: 0.1 - 999.9s

  • Test Time: Off / 0.5s - 999.9s

Email:  info@itesouthafrica.com 

Address:  Unit B1,Sanlam Industrial Park,

 

      Masjien Street,Strydom Park,

Randburg, Gauteng

 

South Africa

Phone:  +27 (0)872658722