ICPS.7000 Automatic Flashpoint Analyser
About the ICPS.7000:
  • Inductively coupled plasma emission spectrometer. It is used to measure traces and traces of various substances (dissolvable in hydrochloric acid, nitric acid, hydrofluoric acid, etc.),and the content of metal elements or non-metallic elements. It is stable and reliable and with high degree of automation and easy operation. At present, instruments are widely applied in various fields such as rare earth, geology, metallurgy, chemical industry, environmental protection, clinical medicine, petroleum products, semiconductor, food, biological samples, criminal science, agricultural research and so on

More about the FT.3000
Specifications:

Shipping/Storage Conditions

  • Ambient Temperature: 15°C to 25°C

  • Relative Humidity: ≤70%

  • Atmospheric Pressure: 86-106 kPa

Power Supply

  • 220±10V, 50-60Hz

Working Conditions

  • Working Humidity: ≤70%

  • Working Temperature: 15°C to 30°C

RF Power Technical Parameters

  • Circuit Type: Solid-state RF power supply, with auto match function

  • Frequency: 27.12 MHz ±0.05%

  • Frequency Stability: <0.1%

  • Power Output: 800W to 1200W

  • Power Output Stability: <0.3%

  • Escaped RF Radiation: 30 cm away from the instrument, electric field: E < 2V/m

Sampling System Technical Parameters

  • Output Working Coil Inner Diameter: 25 mm

  • Torque Tube: Three concentric, external diameter 20 mm

  • Coaxial Nebulizer: Outer diameter 6 mm

  • Double Barrel Atomizing Chamber: Outer diameter 34 mm

Gas Flow Controls

  1. Plasma Argon Flowmeter: 100-1000 L/h (1.6-16 L/min)

  2. Auxiliary Argon Flowmeter: 10-100 L/h (0.16-1.66 L/min)

  3. Carrier Argon Flowmeter: 10-100 L/h (0.16-1.66 L/min)

  4. Oxygen Flowmeter: 0-100 ml/min (30-50 ml/min)

  5. Pressure Maintaining Valve: 0-0.4 MPa

  6. Cooling Water:

    • Temperature: 20-25°C

    • Rate of Flow: >5 L/min

    • Hydraulic Pressure: >0.1 MPa

Spectrometer Optics

  • Type: Czerny-Turner

  • Focal Length: 1000 mm

  • Grating: Ion Beam Etching Holographic Grating, 3600 L/mm or 2400 L/mm

  • Reciprocal Linear Dispersion: 0.26 nm/mm

  • Resolution: ≤0.007 nm (3600 line grating); ≤0.015 nm (2400 line grating)

  • Wavelength Range:

    • 3600 line grating: 190 nm to 500 nm

    • 2400 line grating: 190 nm to 800 nm

  • Minimum Pace of Stepping Motor: ≤0.0006 nm

  • Exit Slit: 12 μm; Entrance Slit: 10 μm

Photoelectric Converter Performance

  • Photomultiplier Tube Specification: R293/R928

  • Negative HV on PMT: 0-1000V

  • Stability: <0.05%