FR.4000 Furanic Transformer Oil Analyser
About the FR.4000:
  • FR.4000 infusion pump - high precision, high stability & efficiency Liquid Chromatography.

  • Widely used in various fields of chromatography analysis.

  • Built on extensive experience and technology, continuously enhancing functionality for experimental needs.

  • Complete with high-pressure infusion pump and ultraviolet detector.

High Pressure Infusion Pump
Specifications:

Flow Range

  • 0.001-10 ml/min (set step width 0.001 ml/min)

Flow Accuracy

  • ±1% or 2 µL/min (0.001-10 ml/min)

Maximum Work Pressure

  • 42.0 MPa (Can set on the top and bottom limitations, automatic alarm)

Flow Precision

  • 0.3%

Gradient

  • Binary or ternary

Gradient Mode

  • Gradient elution (internal software can be self-controlled by PC and pump)

Power Supply

  • AC 110V/220V, 50Hz/60Hz

Dimensions

  • 400 mm × 300 mm × 180 mm

  • Adopts patented static motor control circuit technology for automatic feedback and tracking, improving motor control accuracy and ensuring reliability and stability.

  • Pump form: Double-plunger reciprocating series or parallel.

  • Patented floating self-aligning seal technology and self-cleaning pump head extend seal service life, enhancing durability and cost-effectiveness (online plunger seal cleaning optional).

  • Convenient flow and pressure correction for high accuracy and stability.

  • Two gradient operation program designs: linear gradient and step gradient.

  • Automatic compensation for programmed solvents and compression factors.

  • Complete pre-cleaning function for easy replacement of fast solvents.

Ultraviolet Detector
Specifications:

Lamp

  • Deuterium lamp / tungsten lamp

Optical Route Design

  • Monochromator with dual silicon photodiode detector

Linear Range

  • 2.8AU (5%)

Wavelength Range

  • 190-700nm (Increase 1nm for each step)

Wavelength Repeatability

  • ±0.2nm

Wavelength Accuracy

  • ±1nm

Band Width

  • <6nm

Absorption Range

  • 0.0005AU/mV - 4AU/mV

Data System Output

  • 4AU/V Sampling injection signal control, auto-zero, supporting dual output of integrator and recorder

Baseline Noise

  • ≤±0.5×10⁻⁵ AU (empty pool, 254nm, 1.0s)

Baseline Drift

  • ≤2×10⁻⁴ AU (empty pool, 254nm, 60min stable)

Minimum Detection Concentration

  • 2×10⁻⁹ g/mL (naphthalene in methanol solution)

Sample Cell

  • Analysis cell optical length: 10mm, volume: 10.0μL

Power Supply

  • AC 110V/220V, 50Hz/60Hz

Dimensions

  • 400mm × 300mm × 180mm

  • Holographic double grating technology for easy and fast time and wavelength design

  • Highly precise photodiode design expands the linear range

  • Self-correction of light intensity gain coefficient for convenience and speed

  • Unique holmium glass design with full-wavelength spectrum scanning for accurate wavelength correction

  • Universal sample cell design for easy transition between trace and constant pool

  • Simple and fast replacement of deuterium lamp, no need for correction during use