PC based Online Ceiling Fan Analyzer
Fan_edited.png
PDF Data Sheet

*PDF Currently Unavailable

About the D-9005 CFA:
  • The PC Based Automatic Fan Analyzer is the most comprehensive tester designed to automatically check the quality of Ceiling Fans including the BLDC Fans mounted on the conveyors.

Features:
  • Infinite Model storage capability

  • Job work management area for Test data reference

  • 17 inch DELL monitor display with ADVANTECH Industrial PC

  • LABVIEW software based Application to Test, Store and Print test reports.

  • Permission based Login system

  • Software defined limits for Test parameters

  • Online line support and calibration using remote access software

Benefits:
  • 17 inch colour coded Display screen

  • Audio, visual alarm for faulty Fan

  • Printer can be connected to tester via USB for direct printouts

  • MS Excel Report generation (Pie and Bar charts)

Accesories:
  • Housed in dust free enclosure

  • Inhouse UPS for PC and monitor

PC SPECIFICATIONS:
  • 17 inch DELL make monitor

  • ADVANTECH make Industrial PC

  • 4GB RAM / 500GB HDD

  • Windows 10 / MS Office 2015 / Anti Virus

  • Dust proof / Water resistant / 0-60 C

  • 6 USB ports, VGA port, LAN port

  • Wireless keyboard & mouse

  • NATIONAL INSTRUMENT DAQ cards

Application:

Online Testing of Ceiling fans

SOFTWARE TEST SCREEN:
online-tester-768x588.jpg
Test Specifications:

The Automatic Online Ceiling Fan Analyzer is installed directly on the conveyor, where ceiling fans are tested by applying voltage to the bus bars mounted on the conveyor. The tests are performed in the following sequence:

I) H.V Flash Test (Bus Bar – I)
The H.V Flash test checks the strength of the ground wall insulation at a higher applied voltage than the I.R test. If there is a sudden surge in the leakage current, it indicates weak insulation, and the test fails.

H.V Flash Test Formula:

  • H.V Flash test = (2×E + 1000), where E is the operating voltage

Test Voltage:

  • 0-2.5KV AC (Adjustable)

Test Time:

  • 0-10 sec

Overtrip Leakage Current Limit:

  • 0.1-10 mAmps

II) Low Voltage Start Test (Bus Bar – II)
The Low Voltage Start test is performed at around 100V to check if the fan rotates at low voltage and if there is no jammed rotor inside the fan. The readings of Wattage, Current, and PF are measured and compared against the defined parameters set by the operator.

Test Voltage:

  • 0-270 Volts (Adjustable)

Wattage Limit:

  • 0-2000 Watts

Current Limit:

  • 0-8 Amps

Power Factor Limit:

  • 0.000-1.000

Test Time:

  • 0-10 sec

III) Full Voltage No Load Test (Bus Bar – III)
The Full Voltage No Load Test is performed at full run voltage of around 230V to check the electrical parameters of the ceiling fan. The readings of Wattage, Current, and PF are measured and compared against the defined parameters set by the operator.

Test Voltage:

  • 0-270 Volts (Adjustable)

Wattage Limit:

  • 0-2000 Watts

Current Limit:

  • 0-8 Amps

Power Factor Limit:

  • 0.000-1.000

Test Time:

  • 0-10 sec