top of page
PC Based Automatic Safety Analyzer
Analyzer_edited_edited_edited_edited.png
PDF Data Sheet

*PDF Currently Unavailable

About the D-9009 SF:
  • The PC Based Automatic Safety Analyzer is ideally suited for fast paced production lines delivering high volumes of finished household appliances. This Tester has been appreciated by many household appliance manufacturers in India such as Tecumseh, Havells, Hitachi, IFB, LG, Voltas, Videocon, Yash fans to name a few.

Features:
  • Infinite Model storage capability

  • Job work management area for motor data reference

  • 17 inch DELL monitor display with ADVANTECH Industrial PC

  • LABVIEW software based Application to Test, Store and Print Test Reports

  • Permission based Login system

  • Software Defined Limits for Test Parameters

  • Online line support and calibration using remote access software

  • Bar code/QR code reading facility

Benefits:
  • 17 inch colour coded Display screen

  • Audio, visual alarm for faulty Motor

  • Printer can be connected to tester via USB for direct printouts

  • MS Excel Report generation (Pie and Bar charts)

Accesories:
  • Start/Stop Remote Switch

  • Housed in dust free enclosure

  • Inhouse UPS for PC and monitor

PC SPECIFICATIONS:
  • 17 Inch DELL Make Monitor

  • ADVANTECH Make Industrial PC

  • Windows 10 / MS Office 2015 / Anti Virus

  • Dust Proof / Water Resistant / 0-60 C

  • 6 USB Ports, VGA Port, LAN Port

  • Wireless Keyboard & Mouse

  • NATIONAL INSTRUMENT DAQ Cards

  • NATIONAL INSTRUMENT Temperature Sensor

Application:

This tester is widely used for testing newly and rewound motors. It helps in finding and predicting the faults in motors before it actually happens. This tester is extremely portable that can be easily used in the motor shop and in field to test the following:

  • Motors of Table Fan and Exhaust Fan

  • Motors of Cooler, Blower and Pump

SOFTWARE INDICATOR & CONTROLS:
  • Adjustable Volts/Div and TimeBase

  • Colour coded waveform display

  • Surge test peak voltage indicator

  • Graphical and numerical %error display

  • Target voltage indicator based on motor rating

  • Test result lamp indicator

  • Save, recall and print waveforms & reports

Safety.jpg
Test Specifications:

The Automatic Safety Analyzer performs the tests in the following sequence, and in case of a fault, it stops the sequence of tests and sets off a buzzer alarm to the user.

I) Ground Test
The Ground Efficiency test checks the connection of the cable or ground wire that comes from the plug to the rack of the appliance by applying a 10 volts (A.C) to the circuit terminal and picking up the potential drop across it.

Test Voltage:

  • 10 Volts

Test Current:

  • 25 Amps

Test Time:

  • 0-10 sec

Limit:

  • 0-10 Amps

II) I.R (Megohm) Test
The I.R test checks the strength of the ground wall insulation that can be damaged due to dirt, carbon, moisture, or weak wire insulation.

Test Voltage:

  • 500 Volts (DC)

Test Time:

  • 0-10 sec

I.R Limit:

  • 0-200 MΩ

III) H.V Flash Test
The H.V Flash test checks the strength of the ground wall insulation at a higher applied voltage than the I.R test. If there is a sudden surge in the leakage current, it indicates weak insulation, and the test fails.

H.V Flash Test Formula:

  • H.V Flash test = (2×E + 1000), where E is the operating voltage

Test Voltage:

  • 0-2.5KV AC (Adjustable)

Test Time:

  • 0-10 sec

Overtrip Leakage Current Limit:

  • 0.1-10 mA

IV) Low Voltage (Startability) Test
The Low Voltage test checks the Input current drawn by the appliance at an input voltage specified by the user depending on the type of appliance. The user can also define the upper and lower limits of the input current. If the current is within the specified limits, the test is successful; otherwise, the test sequence stops, and the audio/visual alarm is triggered.

Test Voltage:

  • 0-270 Volts (Adjustable)

Wattage Limit:

  • 0-2000 Watts

Current Limit:

  • 0-8 Amps

Power Factor Limit:

  • 0.000-1.000

Test Time:

  • 0-30 sec

V) Full Voltage Run Test
The Full Voltage Run test also checks the Input current drawn by the appliance at an input voltage specified by the user depending on the type of appliance. The user can also define the upper and lower limits of the input current. If the current is within the specified limits, the test is successful; otherwise, the test sequence stops, and the audio/visual alarm is triggered.

Test Voltage:

  • 0-270 Volts (Adjustable)

Wattage Limit:

  • 0-2000 Watts

Current Limit:

  • 0-8 Amps

Power Factor Limit:

  • 0.000-1.000

Test Time:

  • 0-30 sec

VI) Leakage Current Test
The Leakage current test detects the current existing between the inside circuits with applied voltage and the external metallic parts of the appliance.

Test Voltage:

  • 255 Volts (AC)

Test Time:

  • 0-10 sec

Overtrip Leakage Current Limit:

  • 0.1-10 mAmps

bottom of page