CMP-2000 Clamp Meter

Measurement:
-
AC current measurement (TRUE RMS) up to 1500 A and DC up to 2000 A.
-
Measurement of INRUSH current in start-up phase of electrical device.
-
AC voltage measurement (TRUE RMS) up to 750 V and DC up to 1000 V.
-
Resistance measurement and continuity test:
-
-continuity test with acoustic signalling (beeper) for resistance below 30 Ω.
-
Capacitance measurement
-
Temperature measurement (Fahrenheit or Celsius).
-
Frequency measurement.
-
Duty cycle measurement.
-
Diode test.
Key Features:
-
safe, insulated measuring clamp, (Ø 57 mm or 70 x 18 mm bus bar),
-
autoranging,
-
„DATA HOLD” function, for holding measured values,
-
backlit LCD,
-
„DC ZERO” mode of measurement for DC current, possibility to zero the display and reading relative actual value less stored „zero” value,
-
„MAX/MIN” function,
-
over range indication,
-
„AUTO-OFF” function after 30min.
Specifications:
Electrical safety
- measurement category CAT II 600V acc. to EN 61010-1:2004
- protection class acc. to EN 60529 IP40
Other technical specifications
- power supply .............................................................................9V battery type 6LR61
- display....................................................................................6600 counts, backlit LCD
- continuity test..........................................................................................threshold 30 Ω
- diode test.............test current of 0.8 mA, typical; open circuit voltage 3.2V DC, typical
- low battery indication..............................................................................BAT displayed
- overrange indication................................................................................‘OL’ displayed
- temperature sensor.......................................................................type K thermocouple
- input impedance......................................................................ca.10 MΩ (V DC i V AC)
- AC bandwidth...............................................................................................50...500 Hz
- auto power OFF............................................................................................30 minutes
- dimensions/weight...........................................281 x 108 x 53 mm/570 g (with battery)
- accordance with following standards..............................EN 61010-1; EN 61010-2-032
Rated operational conditions:
- able to open the clamp:.........................................Ø 57 mm wire; 70 x 18 mm bus bar
- operating temperature/storage temperature.............................0...+50 °C/-20...+60 °C
- operating altitude........................................................................................max 2000m
.*For full Technical Specifications, please refer to PDF Data Sheet
Standard Accessories:
- test leads (2 pcs.)
- K type temperature probe
- 9 V battery
- case
- calibration certificate