top of page
CMP-2000  Clamp Meter
CMP-2000 clamp meter
Measurement:
  • AC current measurement (TRUE RMS) up to 1500 A and DC up to 2000 A.

  • Measurement of INRUSH current in start-up phase of electrical device.

  • AC voltage measurement (TRUE RMS) up to 750 V and DC up to 1000 V.

  • Resistance measurement and continuity test:

  • -continuity test with acoustic signalling (beeper) for resistance below 30 Ω.

  • Capacitance measurement

  • Temperature measurement (Fahrenheit or Celsius).

  • Frequency measurement.

  • Duty cycle measurement.

  • Diode test.

Key Features:
  • safe, insulated measuring clamp, (Ø 57 mm or 70 x 18 mm bus bar),

  • autoranging,

  • „DATA HOLD” function, for holding measured values,

  • backlit LCD,

  • „DC ZERO” mode of measurement for DC current, possibility to zero the display and reading relative actual value less stored „zero” value,

  • „MAX/MIN” function,

  • over range indication,

  • „AUTO-OFF” function after 30min.

Specifications:

Electrical safety

- measurement category                                       CAT II 600V acc. to EN 61010-1:2004

- protection class acc. to EN 60529                                                                           IP40

Other technical specifications

- power supply .............................................................................9V battery type 6LR61

- display....................................................................................6600 counts, backlit LCD

- continuity test..........................................................................................threshold 30 Ω

- diode test.............test current of 0.8 mA, typical; open circuit voltage 3.2V DC, typical

- low battery indication..............................................................................BAT displayed

- overrange indication................................................................................‘OL’ displayed

- temperature sensor.......................................................................type K thermocouple

- input impedance......................................................................ca.10 MΩ (V DC i V AC)

- AC bandwidth...............................................................................................50...500 Hz

- auto power OFF............................................................................................30 minutes

- dimensions/weight...........................................281 x 108 x 53 mm/570 g (with battery)

- accordance with following standards..............................EN 61010-1; EN 61010-2-032

Rated operational conditions:

- able to open the clamp:.........................................Ø 57 mm wire; 70 x 18 mm bus bar

- operating temperature/storage temperature.............................0...+50 °C/-20...+60 °C

- operating altitude........................................................................................max 2000m

.*For full Technical Specifications, please refer to PDF Data Sheet

Standard Accessories:

- test leads (2 pcs.)

- K type temperature probe

- 9 V battery

- case

- calibration certificate

CONTACT

Email:  info@itesouthafrica.com 

Address:  Unit B1,Sanlam Industrial Park,

 

               Masjien Street,Strydom Park,

Randburg, Gauteng

 

South Africa

Phone:  +27 (0)872658722

© 2021 ITESA - Industrial Test Equipment South Africa  |  Terms and Conditions  |  Privacy Policy