CMM-40  Industrial Multi-meter
Key Features:

Industrial multimeter CMM-40 was designed for the purpose of measurements of AC/DC voltage, AC/DC current, resistance, capacitance, frequency (electrical and electronic), duty cycle, temperature and also for testing diodes and continuity.

 

  • Autoranging/manual range selection.

  • „DATA HOLD” function, for holding measured values.

  • „REL” function, which allows you to make measurements relative to a stored reference value.

  • „MAX/MIN” function.

  • „PEAK HOLD” function.

  • Memory for 2000 measurement results.

  • Continuity test with acoustic signalling (beeper).

  • „AUTO-OFF” function.

  • Display 4¾ digits (40000 max).

  • Double moulded, waterproof .

Specifications: 

Electrical safety

- type of insulation double,                                    EN 61010-1 and IEC 61557 compliant

- measurement category                                     CAT III 1000V acc. to EN 61010-1:2004

- protection class acc. to EN 60529                                                                            IP67

Other technical specifications

- power supply ..............................................................................9V battery type 6LR61

- diode test................................................................................. I=0,9mA, U =2,8V DC 0

- continuity test.......................................................... I<0,35mA, sound signal for R<35Ω

- over range indication .................................................................................0L displayed

- crest factor.......................................................................... ≤ 3 at full scale up to 500V,

                                                                               decreasing linearly to ≤ 1,5 at 1000V

- PEAK captures peaks.......................................................................................... >1ms

- sampling rate.................................................................................. 2 times per second

- input impedance ................................................................10MΩ (V DC), 9MΩ (V AC)

- display ..........................................40000 counts backlit LCD with bargraph, 4¾ digits

- store capacitance .................................................................................................2000

- dimensions .......................................................................................187 x 81 x 55 mm

- weight.................................................................................................................. 342 g

- fuses .....................................................mA, μA range: 0,5A/1000V ceramic fast blow

                                                                           A range: 10A/1000V ceramic fast blow

- auto power OFF ................................................................................................15 min.

- accordance with following standards ...............................................EN 61010-1:2004

                                                                                                              EN 61010-2-032

- quality standard............................................................................................. ISO 9001

Rated operational conditions:

- operating temperature................................................................................... 0...+40°C

- storage temperature ...................................................................................-20...+60°C

- operating humidity ............................................................max 80% up to 87°F (31°C)

                                                                     decreasing linearly to 50% at 104°F (40°C)

- operating altitude ........................................................................................max 2000m

.*For full Technical Specifications, please refer to PDF Data Sheet

Standard Accessories: 

- test leads (2 pcs.)

- battery 9V

- K type temperature probe

- carrying case

- waterproof plugs (2 pcs.)

- operating manual